The real question
Which pressure belongs to the bore, and which to the side outlet?
Read the body in three zones: lower connection to the casing stack, internal bowl for hanger/seal, and upper connection to adapter or tree; side outlets communicate with the annulus.
Technical model
Bowl and shoulder
The internal geometry lands the hanger and transfers load. Compatibility is not established by visible diameter alone and must come from manufacturer documentation.
Side outlets
They support annulus monitoring, bleed-off, injection or testing; valve status and the downstream route must be known before operation.
Upper and lower boundaries
Each connection must match its mate in bore, pressure class, facing, ring groove and material/service requirements.
Controlled sequence
From identification to evidence
- 01Verify drawing↓
- 02Inspect bowl↓
- 03Install spool↓
- 04Test seal/outlet
Field application
What does this change in the field?
The nameplate, GA drawing, datasheet and pressure-test procedure must describe the same equipment identity.
Glossary
Key terms
- Tubing head
- Wellhead body that supports the hanger and bounds the annulus.
- Side outlet
- Controlled lateral connection from the spool body.
Learning check
Reason through the operating case
Why can an open outlet remain hazardous even when the tree is shut?
Answer and reasoning
Because the outlet communicates with a potentially pressurised annulus; shutting the production path does not necessarily isolate it.
Technical sources
The sequence is based on Eng. Kamal Deilami’s wellhead equipment reference and cross-checked against official manufacturer and technical sources. It does not replace manufacturer instructions or the approved well programme.